1
First Decision
How to Order
The ordering code for JAE/JRE/JLE F-Frame Circuit Protectors
may be determined by following the steps in the decision tables
shown here.
JLE
JLM
JRE
Type
UL Listed
UL Listed Mid Trip Construction
UL Recognized
The coding given permits a self-assigning part number for
standard configurations. Factory part numbers are assigned to
units with mixed ratings, combinations of styles or construction
not listed in the Third Decision Table, etc. With these, it is
suggested that order entry be by description and/or drawings,
and a part number will be established.
Additionally, it is standard policy to establish a factory-assigned
part number whenever a descriptive drawing exists to ensure
cross reference, traceability and manufacturing control.
For example, the following is the code for a single pole breaker
series trip, with mid-trip handle indication, auxiliary switch, short
delay, 65 volts DC maximum voltage rating with 3/8-16 captive nuts
in a current rating of 250 amperes and metric inserts.
To determine the ordering number of your particular JAE/JRE/
JLE unit, simply follow the steps shown. You may use this
number to place an order or as a reference for further questions
you may have.
JREP
JRM
JRMP
JTE
JTEP
JTM
JTMP
JAE
JAEP
JAM
JAMP
UL Recognized above 250 amps
UL Recognized Mid Trip
Construction
UL Recognized Mid Trip
Construction above 250 amps
UL Listed Telecom Speci cation
UL Listed Telecom Speci cation
above 250 amps
UL Listed Telecom Speci cation
Mid Trip Construction
UL Listed Telecom Speci cation
Mid Trip Construction above
250 amps
Non Agency
Non Agency above 250 amps
Non Agency Mid Trip
Construction
Non Agency Mid Trip
Construction above 250 amps
Notes:
A 10-32 inserts are provided for front mounting on all units. M5 ISO metric mounting
inserts are available and are specified by the eight decision in the part number.
B The auxiliary switch is located on the left hand pole (viewed from terminal end)
unless specified otherwise. Note this is the only location available for breakers
rated over 250 amps. The switch is available as an alarm switch (changes
state when breaker electrically trips) or as an auxiliary switch (changes state
when the breaker contacts change state either from tripping or operation of
the breaker handle). See outline drawing for location of alarm and auxiliary
switches. Note alarm switches are available only with mid trip option. When
both an alarm and auxiliary switch are specified with a metering shunt, only
the C and NO or C and NC terminals from each switch are available for field
termination.
C 3/8-16 captive nuts are available for bus bar terminations or crimp lugs
(specify front or back termination). 3/8-16 long and short studs are also
available (specify front or back mount). A number 6 through 300 MCM AL/CU
solderless connector is available (specify front or back mount).
D Only series construction and DC ratings are available in current carrying poles
above 250 amps. Consult factory for special requirements.
E The coding given permits a self-assigning part number but with certain
limitations, (due to the adaptability of magnetic protectors to complex circuits)
which require a need for a factory assigned part number. Typical examples
are units with mixed ratings, combinations of styles, or construction not listed
in the third decision table, etc. With these, it is suggested that order entry
be by description and/or drawings, and a part number will be established.
Additionally, it is standard policy to establish a factory assigned part number
wherever a descriptive drawing exists to provide cross-reference, traceability,
and manufacturing control.
F When specifying a protector for AC motor start or high inrush applications, the
peak amplitude and surge duration should be specified for factory assistance
in rating selection.
G Since magnetic protectors with time delay are somewhat attitude and
temperature sensitive, all trip curves and trip currents are specified with the
protector mounted in the normal vertical position at ambient temperature
of 25°C. Protectors do not carry current prior to application of overload for
calibration test. For other than vertical mount position, consult factory.
H A 25mV at rated current non-isolated metering shunt is available as an option
(see outline drawing). The shunt accuracy is 1% full scale 25°C ambient.
I
Dual coil construction is available. Consult the factory.
J Decisions referencing this note may be replaced by a factory assigned
nondescript number.
203
JAE Series - Decision Tables
http://airpax.sensata.com
相关PDF资料
JM0300 MOUSE OPTICAL USB ILLUM BLUE
K15A-0101 MONITOR TRU 15" TOUCH OPEN FRAME
K17A-0101 MONITOR TRU 17" TOUCH OPEN FRAME
K21A-0201 MON TRU SLIM 21.5" TOUCH OPEN
K21A-1201 MON TRU SLIM 21.5" TOUCH DESKTOP
K32A-0111 MONITOR TRU SLIM 32" TOUCH DESKT
KBCV7000W PLAST KEYBD COVER G81-7000 MODEL
KIT10XS3535EVBE KIT EVAL BOARD FOR 10XS3535
相关代理商/技术参数
JLE-2-1-53-4-F1-250 制造商:Sensata Technologies 功能描述:JLE-2-1-53-4-F1-250 /Pole # 2 /Prod Family: 0218
JLE-2-1-53F-2-B3-200 制造商:Sensata Technologies 功能描述:JLE-2-1-53F-2-B3-200 /Pole # 2 /Prod Family: 0218
JLE-2-1-61-5-B1-120 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 2Pole 120A 240VAC
JLE-2-1-61-5-B3M-125-A 制造商:Sensata Technologies 功能描述:JLE-2-1-61-5-B3M-125-A /Pole # 2 /Prod Family: 0218
JLE-2-1-61-5-B3M-180-A 制造商:Airpax 功能描述:SENSATA 制造商:Sensata Technologies 功能描述:JLE-2-1-61-5-B3M-180-A /Pole # 2 /Prod Family: 0218
JLE-2-1-61-5-B4-125 制造商:Sensata Technologies 功能描述:JLE-2-1-61-5-B4-125 /Pole # 2 /Prod Family: 0218
JLE-2-1-62-5-B3-135 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 2Pole 135A 240VAC
JLE-2-1-62-5-B4-105 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 2Pole 105A 240VAC